Same as 807322W, but with an individual combination of up to 5 languages, see special order form in the appendix.
Addressable, completely bus supplied and short circuit / open circuit resilient voice sounder in compliance with EN 54‑3 with integrated voice messages and signaling tones for acoustic alarm signaling.
With up to 20 different programmable signaling tones including DIN tone in accordance with DIN 33404 Part 3.
Speech alarm with 5 pre-programmed alarm messages in 5 different languages.
The volume can be set to 8 different levels.
Selection or combination of speech messages and signaling tones as well the volume control are carried out via the tools 8000 programming software.
Signaling device with flat base, suitable for wall and ceiling mounting.
Optionally, IP base Part No. 806201 with side cable entry and weatherproof protection can be instalSame as 807322W, but with individual text and/or sounds. The maximum recording time per device is 169 seconds.
Addressable, completely bus supplied and short circuit / open circuit resilient voice sounder in compliance with EN 54-3 with integrated voice messages and signaling tones for acoustic alarm signaling.
With up to 20 different programmable signaling tones including DIN tone in accordance with DIN 33404 Part 3.
Speech alarm with 5 pre-programmed alarm messages in 5 different languages.
The volume can be set to 8 different levels.
Selection or combination of speech messages and signaling tones as well the volume control are carried out via the tools 8000 programming software
Signaling device with flat base, suitable for wall and ceiling mounting.
Optionally, IP base Part No. 806201 with side cable entry and weatherproof protection can be installed.
Same as 807322W, but with individual text and/or sounds. The maximum recording time per device is 169 seconds.
Addressable, completely bus supplied and short circuit / open circuit resilient voice sounder in compliance with EN 54-3 with integrated voice messages and signaling tones for acoustic alarm signaling.
With up to 20 different programmable signaling tones including DIN tone in accordance with DIN 33404 Part 3.
Speech alarm with 5 pre-programmed alarm messages in 5 different languages.
The volume can be set to 8 different levels.
Selection or combination of speech messages and signaling tones as well the volume control are carried out via the tools 8000 programming software
Signaling device with flat base, suitable for wall and ceiling mounting.
Optionally, IP base Part No. 806201 with side cable entry and weatherproof protection can be install
Addressable, completely bus supplied and short circuit / open circuit resilient combined fire alarm sounder and Visual Alarm Device (VAD) in compliance with EN 54-3 & EN 54-23 with integrated signaling tones and red light flash for acoustic and optical alarm signaling.
With up to 20 different programmable signaling tones including DIN tone in accordance with DIN 33404 Part 3.
The volume can be set to 8 different levels.
The optical signalling device is suitable for square signal ranges W-2.4-5 to W-3.6-8.
The optical signal range is adjustable in 6 sizes via tools 8000.
Signaling device with flat base, suitable for wall mounting.
Optionally, IP base Part No. 806202 with side cable entry and weatherproof protection can be installed.
Same as 807372RW, but with an individual combination of up to 5 languages, see special order form in the appendix.
Addressable, completely bus supplied and short circuit / open circuit resilient combined voice sounder and Visual Alarm Device (VAD) in compliance with EN 54‑3 & EN 54‑23 with integrated voice messages, signaling tones and white light flash for acoustic and optical alarm signaling.
With up to 20 different programmable signaling tones including DIN tone in accordance with DIN 33404 Part 3.
Speech alarm with 5 pre-programmed alarm messages in 5 different languages.
The volume can be set to 8 different levels.
Selection or combination of speech messages and signaling tones as well the volume control are carried out via the tools 8000 programming software
The optical signaling device is suitable for square signal ranges W‑2.4‑5 to W‑3.6‑8.
The optical signal range is adjustable in 6 sizes via tools 8000.
Signaling device with flat base, suitable for wall mounting.
Optionally, IP base Part No. 806202 with side cable entry and weatherproof protection can be installed.
Same as 807372RW, but with individual texts and/or sounds. The maximum recording time per device is 169 seconds.
Addressable, completely bus supplied and short circuit / open circuit resilient combined voice sounder and Visual Alarm Device (VAD) in compliance with EN 54‑3 & EN 54‑23 with integrated voice messages, signaling tones and white light flash for acoustic and optical alarm signaling.
With up to 20 different programmable signaling tones including DIN tone in accordance with DIN 33404 Part 3.
Speech alarm with 5 pre-programmed alarm messages in 5 different languages.
The volume can be set to 8 different levels.
Selection or combination of speech messages and signaling tones as well the volume control are carried out via the tools 8000 programming software
The optical signaling device is suitable for square signal ranges W‑2.4‑5 to W‑3.6‑8.
The optical signal range is adjustable in 6 sizes via tools 8000.
Signaling device with flat base, suitable for wall mounting.
Optionally, IP base Part No. 806202 with side cable entry and weatherproof protection can be installed