IQ8Alarm optical alarm signaling device, red

807214

Approval: VdS

As 807212, but red.
  • Completely bus supplied alarm device
  • Powered loop compatible
  • Low power consumption
  • 5 different signaling device types - acoustic - optical- acoustic / optical- acoustic / optical- acoustic / optical / speech
  • Multilingual speech alarm in 5 different languages
  • Alarm signaling, evacuation, and test alarm can each be programmed in different languages
  • Up to 32 alarm devices for each powered loop
  • Each alarm device has built-in isolator
  • Individual control of the sounder and beacon
  • Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools etc.
  • Soft start option, ideal for hospitals and nursing homes

Acoustic alarm signaling:
  • Acoustic pressure up to 99 dB(A) @ 1 m
  • Volume programmable in 8 steps via tools 8000
  • Up to 26 different languages are available
  • 20 different signaling tones, including DIN tone
  • Speech alarm, 5 pre-programmed alarm texts and other country-typical alarm signals


Optical alarm signaling:
  • Flash intensity equivalent to 3W Xenon flash light
  • Light intensity: max. 3.87 cd effective, max. 24 cd peak

Additional Information:
Please consider:
  • Admissible maximum loop length
  • Admissible maximum number of single alarm device types
  • Maximum number of 127 bus devices for each loop
Systems requirements: FACP IQ8Control from version V3.04 FACP FlexES Control esserbus-Plus functionality Programming software tools 8000 from version V1.09 Attention - an operation with the FACP'S 8000 C/M is not possible!!!
For upgrading 8000 C/M control units, IQ8Lumivox signaling devices must be used. If required, please contact our returns department. For checking the battery capacity of FACP, the value “quiescent current @ FACP battery“ can be added.
Phase out date 31.12.2014
Operating voltage 8 ... 42 V DC (via powered loop)
Lighting energy approx. 3 Y
Frequency of flash approx. 3 Hz
Color base, cap: red, similar to RAL 3020
Housing ABS plastic
Weight
approx. 300 g
Storage temperature -10 °C ... 55 °C
Load factor 3
Luminous intensity max. 20.91 Cd peak/3.41Cd effective
Air humidity < 95 % (non-condensing)
Quiescent current @ 19 V DC approx. 55 μA
Quiescent current @ FACP battery approx. 300 μA @ 42 V
Type of protection IP 30; IP 65 (with base 806201/806202)
Ambient temperature -10 °C ... 50 °C
VdS class F
VdS-Nr G 206002
Dimensions ø: 112 mm D: 90 mm (with IP 65 base)
806202 IP65 base, red